Huadong cable as the best 7/32” 5.69 mm Monoconductor armor wireswireline cable manufacturer in China. And 7/32” (5.69 mm) Monoconductor 1K22 is a type of our logging cable. Because we often export 7/32” (5.69 mm) electromechanical cable to Australia, UK, Iran, Iraq, America and so on. So if you want to find the best wireline cable manufacturer, Huadong cable is your better choice. We can customize the same quality as Camesa wireline brand.
Cable Diameter: 0.322” +0.005” – 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 18” (46 cm)
Cable Stretch Coefficient: 1.2 ft/Kft/Klbs
Maximum Conductor Voltage: 1,500 VDC
Conductor AWG Rating: 16
Minimum Insulation Resistance: 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)
sales@huadongacsr.comConstruction Characteristics | ||||||||||||
English | Metric | |||||||||||
Conductor – 16 AWG, 19 x 0.0119” | 0.059” | 1.499 mm | ||||||||||
Insulation – OD | 0.108” | 2.743 mm | ||||||||||
Inner Armor (GIPS) 12 Wires @ 0.031” | 0.162” | 4.115 mm | ||||||||||
Outer Armor (GIPS) 18 Wires @ 0.031” | 0.224” | 5.690 mm |
Electrical Characteristics | ||||||||||||
English | Metric | |||||||||||
Voltage Rating | 1,200 VDC | 1,200 VDC | ||||||||||
DC Conductor Resistance at 68°F (20°C) | 4.0 Ω/kft | 13.1 Ω/km | ||||||||||
DC Armor Resistance at 68°F (20°C) | 4.4 Ω/kft | 14.4 Ω/km | ||||||||||
Minimum Insulation Resistance | 1,500 MΩ*kft | 457 MΩ*km |
7/32” (5.69 mm) Monoconductor 1K22 Wireline Cable
The 7/32” 5.69 mm Monoconductor are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection during shipping and storing. Wires are preformed.
Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
SUPERSEAL, a special pressure seal agent, is applied between armor layers.
The temperature rating assumes a normal gradient for both temperature and weight.
All values shown are nominal or typical values.
where to find the best 7/32” 5.69 mm Monoconductor 1K22?
While 7/32” 5.69 mm Monoconductor’s insulation is rated to 1-hour exposure of 500°F, alloy armor wires may have reduced corrosion resistance at temperatures above 450°F.
The armor wires are made of corrosion resistant alloy steel suitable for extreme H2S and CO2 environments.
Conductor has nickel plated wires adhering to ASTMB355 Class 10 for increased corrosion resistance.
Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68° F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
SUPERSEAL, a special pressure seal agent, is applied between armor layers.
The temperature rating assumes a normal gradient for both temperature and weight.
All values shown are nominal or typical values.